Martin Zlocha, Qi Dou, Ben Glocker

2019-06-05Medical Object DetectionRegion ProposalComputed Tomography (CT)Lesion Detection
PaperPDFCodeCodeCode

Abstract

Accurate, automated lesion detection in Computed Tomography (CT) is an important yet challenging task due to the large variation of lesion types, sizes, locations and appearances. Recent work on CT lesion detection employs two-stage region proposal based methods trained with centroid or bounding-box annotations. We propose a highly accurate and efficient one-stage lesion detector, by re-designing a RetinaNet to meet the particular challenges in medical imaging. Specifically, we optimize the anchor configurations using a differential evolution search algorithm. For training, we leverage the response evaluation criteria in solid tumors (RECIST) annotation which are measured in clinical routine. We incorporate dense masks from weak RECIST labels, obtained automatically using GrabCut, into the training objective, which in combination with other advancements yields new state-of-the-art performance. We evaluate our method on the public DeepLesion benchmark, consisting of 32,735 lesions across the body. Our one-stage detector achieves a sensitivity of 90.77% at 4 false positives per image, significantly outperforming the best reported methods by over 5%.

Results

TaskDatasetMetricValueModel
Object DetectionDeepLesionSensitivity82.36Improved RetinaNet
3DDeepLesionSensitivity82.36Improved RetinaNet
2D ClassificationDeepLesionSensitivity82.36Improved RetinaNet
2D Object DetectionDeepLesionSensitivity82.36Improved RetinaNet
16kDeepLesionSensitivity82.36Improved RetinaNet

Related Papers

From Variability To Accuracy: Conditional Bernoulli Diffusion Models with Consensus-Driven Correction for Thin Structure Segmentation2025-07-17Latent Space Consistency for Sparse-View CT Reconstruction2025-07-15Enhancing Synthetic CT from CBCT via Multimodal Fusion and End-To-End Registration2025-07-08$μ^2$Tokenizer: Differentiable Multi-Scale Multi-Modal Tokenizer for Radiology Report Generation2025-06-30Opportunistic Osteoporosis Diagnosis via Texture-Preserving Self-Supervision, Mixture of Experts and Multi-Task Integration2025-06-25SAM2-SGP: Enhancing SAM2 for Medical Image Segmentation via Support-Set Guided Prompting2025-06-24Learning from Anatomy: Supervised Anatomical Pretraining (SAP) for Improved Metastatic Bone Disease Segmentation in Whole-Body MRI2025-06-24Adaptive Multi-resolution Hash-Encoding Framework for INR-based Dental CBCT Reconstruction with Truncated FOV2025-06-14